Statements (44)
Predicate | Object |
---|---|
gptkbp:instanceOf |
Standard Test Method
|
gptkbp:appliesTo |
columns
ceilings floors walls beams |
gptkbp:developedBy |
gptkb:ASTM_International
|
gptkbp:firstPublished |
1960
|
gptkbp:hasArea |
fire resistance of building elements
|
https://www.w3.org/2000/01/rdf-schema#label |
ASTM E119
|
gptkbp:includes |
structural integrity
thermal insulation test specimens fire exposure |
gptkbp:influences |
fire safety regulations
|
gptkbp:isPartOf |
construction standards
material science safety engineering fire safety standards fire protection engineering performance-based design building science fire testing standards |
gptkbp:isReferencedBy |
gptkb:UFC
gptkb:NFPA_5000 IBC |
gptkbp:isTrainedIn |
laboratories
research institutions manufacturers |
gptkbp:isUsedBy |
architects
engineers building inspectors contractors fire marshals |
gptkbp:measures |
temperature rise
time to failure |
gptkbp:provides |
fire rating
|
gptkbp:providesGuidanceOn |
fire resistance ratings
|
gptkbp:publishedIn |
Annual Book of ASTM Standards
|
gptkbp:renovated |
multiple times
|
gptkbp:requires |
controlled conditions
|
gptkbp:usedFor |
material selection
design purposes |
gptkbp:usedIn |
building codes
|