gptkbp:instanceOf
|
gptkb:nuclear_reactor
|
gptkbp:capacity
|
1117 MWe
|
gptkbp:competitor
|
gptkb:EPR
gptkb:APR-1400
gptkb:VVER-1200
|
gptkbp:constructionDelays
|
gptkb:Vogtle_units_3_and_4
|
gptkbp:containmentSpraySystem
|
passive containment cooling
|
gptkbp:coolingSystem
|
light water
|
gptkbp:coreDamageFrequency
|
less than 1 in 1,000,000 per reactor year
|
gptkbp:countriesWithUnits
|
gptkb:China
gptkb:India
gptkb:United_Kingdom
gptkb:United_States
|
gptkbp:countryOfOrigin
|
gptkb:United_States
|
gptkbp:designedBy
|
gptkb:Westinghouse_Electric_Company
|
gptkbp:designedFor
|
seismic events
60-year operating life
aircraft impact
station blackout
|
gptkbp:emergencyCoreCooling
|
passive core cooling system
|
gptkbp:emergencyPower
|
passive systems for 72 hours
|
gptkbp:features
|
passive safety systems
|
gptkbp:firstCommercialOperation
|
2018
|
gptkbp:firstCommercialUnitLocation
|
Sanmen Nuclear Power Station, China
|
gptkbp:fuelCycleLength
|
18 months
|
gptkbp:fuelType
|
enriched uranium dioxide
|
gptkbp:generation
|
Generation III+
|
gptkbp:hasConcept
|
157 fuel assemblies
|
https://www.w3.org/2000/01/rdf-schema#label
|
AP1000
|
gptkbp:laps
|
2
|
gptkbp:mainContractorForChinaUnits
|
gptkb:State_Nuclear_Power_Technology_Corporation
|
gptkbp:mainContractorForUSUnits
|
gptkb:Westinghouse_Electric_Company
|
gptkbp:mainTurbineType
|
tandem-compound, four-flow, moisture-separator reheater
|
gptkbp:notableCollection
|
steel containment vessel
|
gptkbp:notableProject
|
gptkb:Haiyang_Nuclear_Power_Plant
gptkb:Sanmen_Nuclear_Power_Station
gptkb:Summer_Nuclear_Generating_Station
gptkb:Vogtle_Electric_Generating_Plant
|
gptkbp:pressurizer
|
vertical, electric heaters
|
gptkbp:primaryCirculationPumps
|
4 canned motor pumps
|
gptkbp:reactorPressureVesselMaterial
|
forged steel
|
gptkbp:reactorType
|
gptkb:nuclear_reactor
|
gptkbp:refuelingInterval
|
18-24 months
|
gptkbp:regulates
|
gptkb:U.S._Nuclear_Regulatory_Commission
gptkb:China_National_Nuclear_Safety_Administration
|
gptkbp:shutdownSystem
|
control rods
|
gptkbp:steamGenerators
|
2
|
gptkbp:steamSupplySystem
|
integral reactor coolant system
|
gptkbp:thermalCapacity
|
3400 MWth
|
gptkbp:bfsParent
|
gptkb:Pressurized_Water_Reactor
gptkb:Vogtle_Electric_Generating_Plant
|
gptkbp:bfsLayer
|
6
|