Fukushima Daiichi Unit 3

E231223

Fukushima Daiichi Unit 3 is one of the damaged reactors at Japan’s Fukushima Daiichi Nuclear Power Plant, known for suffering a hydrogen explosion and core meltdown during the 2011 nuclear disaster.

All labels observed (4)

How this entity was disambiguated

Statements (48)

Predicate Object
instanceOf boiling water reactor
nuclear reactor unit
accidentConsequence core meltdown
hydrogen explosion
accidentDate 2011-03-11
accidentType loss-of-coolant accident
commercialOperationStartDate 1976
constructionStartDate 1967
containmentType Mark I containment
containmentVenting attempted containment venting during accident
coolingLossCause tsunami-induced station blackout
country Japan
decommissioningStatus under decommissioning
earthquakeMagnitude 9.0
electricalCapacity_MWe 784
emergencyResponse sea-water injection into reactor core
firstGridConnectionDate 1974
fuelType mixed oxide fuel
uranium dioxide
gridConnectionStatus_postAccident disconnected from grid
hydrogenExplosionDate 2011-03-14
hydrogenExplosionEffect release of radioactive materials to environment
severe damage to reactor building superstructure
INESRating_contextPlant part of site rated level 7 on INES scale
location Ōkuma, Fukushima Prefecture, Japan
neighboringUnits Fukushima Daiichi Unit 2
Fukushima Daiichi Unit 4
operator TEPCO
Tokyo Electric Power Company
partOf Fukushima Daiichi Nuclear Power Plant
postAccidentStatus fuel debris present in reactor pressure vessel and containment
reactorSupplier Toshiba
reactorType BWR-3
regulatoryBody Nuclear Regulation Authority of Japan (post-reorganization)
Nuclear and Industrial Safety Agency of Japan (at time of accident)
remoteDebrisRemoval used remote-controlled equipment for rubble removal
safetySystemFailure failure of emergency core cooling
loss of off-site power
shutdownReason Fukushima Daiichi nuclear disaster
siteReactorCount one of six reactors at Fukushima Daiichi
spentFuelPoolLocation upper part of reactor building
spentFuelPoolStatus_postAccident intact but structurally affected by explosion
status permanently shut down
thermalCapacity_MWt 2381
tsunamiCause 2011 Tōhoku earthquake
tsunamiDate 2011-03-11
uniqueFeature only MOX-fueled unit at Fukushima Daiichi at time of 2011 accident
usesMOXFuel true

How these facts were elicited

Referenced by (6)

Full triples — surface form annotated when it differs from this entity's canonical label.

Fukushima Daiichi nuclear disaster affectedReactor Fukushima Daiichi Unit 3
Fukushima Daiichi Unit 2 sisterUnit Fukushima Daiichi Unit 3
GE Mark I usedIn Fukushima Daiichi Unit 3
Unit 3 reactor building alsoKnownAs Fukushima Daiichi Unit 3 reactor building
linked to: Fukushima Daiichi Unit 3
BWR-3 usedIn Fukushima Daiichi Nuclear Power Plant Unit 3
linked to: Fukushima Daiichi Unit 3
BWR-3 notableEventAssociation Fukushima Daiichi nuclear accident (Unit 3)
linked to: Fukushima Daiichi Unit 3